Rack Fire Suppression Device
Rack Fire Suppression Device is a simple, efficient and reliable automatic fire extinguishing system. It does not require an external power supply or complex detection equipment. It directly senses the fire source and releases the fire extinguishing agent through a flexible fire detection tube. It uses the temperature sensing characteristics of the fire detection tube. When a fire occurs, the fire detection tube is heated and ruptured, and the fire extinguishing device is quickly activated to spray the fire extinguishing agent directly to the fire source, effectively extinguishing the initial fire.
Rack Fire Suppression Device is an automatic, localized Rack Fire Suppression Device integrated directly into or around individual server racks or enclosures. The goal is to contain and extinguish fires before they spread, minimizing downtime and damage to critical IT infrastructure.Rack Fire Suppression System are engineered to respond quickly and efficiently to localized fires without affecting the entire room or facility.
Rack Fire Suppression Device is widely used in areas with high fire safety requirements such as electronic equipment rooms, communication rooms, power plants, telecommunications cabinets, and server rooms. It is particularly suitable for unattended places and can respond quickly at the initial stage of a fire to reduce economic losses and equipment damage.
FIRE TRACE TUBE EXTINGUISHER SPECIFICATION |
Product Name |
rack fire suppression device |
Model NO |
JGQ2/1.6-XJ |
Cylinder Color |
Red |
Specification |
FM200 Clean Agent |
Working Pressure |
FM200: 4.2MPa |
Origin |
Guangzhou, Guangdong, China |
Trademark |
Xingjin / OEM |
Company Type |
manufacturer over 15-years |
Storage Pressure(20ºC) |
2.5Mpa |
Max. Working Pressure |
4.2Mpa |
Storage of container |
2L |
Max. Filling Rate |
1.15Kg/L |
Working Temperature |
0ºC~50ºC |
Packaging Details |
Plywood Outer Box With Bubble Bag Or Paper |
Pattern Of Extinguishing |
Enclosed Flooding |
Extinguishing Agent |
FM200 |
Durability |
High |
Installation |
Easy To Install |
Safety |
High |
Starting Mode |
Automatic |
Supply Ability |
30000 Set/Sets Per Week |
Mini Order |
5 Set |
We support customized fire extinguishers of various types and uses. |
AUTOMATIC DETECTION AND RAPID RESPONSE
Thanks to advanced sensing technology and intelligent control algorithms, the Rack Fire Suppression Device can identify the source of fire and extinguish it accurately in a very short time, greatly shortening the time interval from fire to control. Server-rack fire suppression device can quickly respond to the early stage of the fire and effectively extinguish the fire source.
ACCURATE FIRE EXTINGUISHING
Rack Fire Suppression Device by rationally arranging detection points and optimizing nozzle direction design, it is possible to focus on protecting specific areas, thereby avoiding waste of resources and improving fire-fighting efficiency.The fire extinguishing agent is directly sprayed to the fire source, avoiding the problem of uneven distribution of the fire extinguishing agent or delayed response in the traditional fire extinguishing system, and the fire extinguishing effect is more accurate and efficient.
FLEXIBLE DESIGN
The Rack Fire Suppression Device can be flexibly arranged and can be extended into a small space, inside the equipment or in a complex area, close to the protected object, and achieve local protection. It is particularly suitable for places with high space requirements.
ADVANTAGES OF RACK FIRE SRPPRESSION
1. Quick response: The Rack Fire Suppression Device can be quickly activated when a fire occurs, extinguish the fire source in time, and prevent the fire from spreading.
2. Efficient fire extinguishing: The use of special fire extinguishing agents can quickly extinguish the flames and reduce fire losses.
3. Easy maintenance: The Rack Fire Suppression Device design makes the device compact, and installation and maintenance are very convenient.
4. High reliability: The Rack Fire Suppression Device is manufactured with high-quality materials and advanced processes to ensure long-term stable operation.
SIMPLE MAINTENANCE
The Rack Fire Suppression Device has a simple structure, does not require a complex installation and debugging process, and has low daily maintenance costs. The fire detection tube has a long service life and is not easily affected by the environment, which reduces the maintenance workload and replacement frequency.


Q1: Are Rack Fire Suppression Device effective on all types of fires?
A1: While rack fire suppression device are highly effective on flammable liquid fires and fires involving solid combustibles, their use may be limited or require additional precautions on certain fires, such as electrical fires or reactive metal fires.
Q2: How often should Rack Fire Suppression Device be maintained?
A2: The maintenance cycle of the rack fire suppression deviceis generally once every six months, but the specific cycle should also be determined according to the equipment use environment and actual operation conditions. If the equipment is abnormal or fails during operation, it should also be maintained and repaired in time. Maintenance operations should be carried out in accordance with the requirements of the equipment manual to avoid damage or failure of the equipment due to misoperation. Safety matters should be paid attention to during maintenance, such as power off and fire prevention, to ensure that the maintenance process does not cause safety hazards to personnel and equipment.
Q3: Can Rack Fire Suppression Device be used in portable form?
A3: The rack fire suppression device is a fire extinguishing device developed according to the size of the cabinet. Rack fire suppression device is embedded in the power distribution cabinet or cabinet, and is vertically packaged and does not require the installation of external pipes and nozzles. It is a highly integrated micro fire extinguishing equipment that integrates fire detection and fire extinguishing.
Q4: What is the working principle of the Rack Fire Suppression Device?
A4: The rack fire suppression device uses advanced fire extinguishing technology. When the protected equipment catches fire, the rack fire suppression device detects the fire source through smoke and temperature. When the fire is detected, it can be quickly activated and the fire extinguishing agent can be sprayed to extinguish the fire. At the same time, it also has automatic detection and alarm functions to timely discover and deal with fire hazards and ensure the safety of equipment and data.